R-Value Insulation Calculator
Calculate the total R-value, RSI, and U-factor of a multi-layer wall, roof, or floor by adding up insulation and building layers, using published US DOE and ASHRAE values, plus the heat flow through it.
Layers
List every layer heat passes through, inside to outside. Insulation uses R-per-inch ranges from the US DOE; fixed layers and air films use ASHRAE design values. For a specific product, use its labeled R-value as a custom layer.
- 1
Layer: R-0.68
- 2
Layer: R-0.45
- 3
R-2.9 – 3.8/in · Layer: R-10.15 – 13.3
- 4
Layer: R-0.62
- 5
Layer: R-0.17
Results
Total R-value
R-12.07 – 15.22
h·ft²·°F/Btu
Total RSI
2.13 – 2.68
m²·K/W
Shown as a range because the DOE table gives a range of R per inch for some materials. Use the product's labeled R-value as a custom layer to get a single number.
Layers are added in series (clear-cavity / center-of-cavity value). Studs, joists, and other framing conduct more heat, so a whole-assembly value is lower.
Usage examples
R-value of a 2x4 wall with fiberglass batts
The default layers are an inside air film (0.68), 1/2" gypsum (0.45), 3.5" of standard fiberglass batt (R-10.15 to R-13.3), 7/16" OSB (0.62), and an outside air film (0.17). The center-of-cavity total is R-12.07 to R-15.22, RSI 2.13 to 2.68, and a U-factor of about 0.066 to 0.083.
Adding 1 inch of XPS continuous insulation
Add a layer of extruded polystyrene (XPS) board at 1 inch to the same wall. XPS is listed at R-5 per inch, so the total rises to R-17.07 to R-20.22 and the U-value drops to about 0.28 to 0.33 W/m²·K.
Checking an attic with 10 inches of blown cellulose
Use an inside air film for a ceiling (0.61), 1/2" gypsum (0.45), and 10 inches of loose-fill cellulose (R-2.9 to R-3.4 per inch). The total is R-30.06 to R-35.06, which you can compare with the attic level your local energy code calls for.
Working in millimeters with EPS board
Switch to metric, choose EPS board, and enter 100 mm. The DOE range of R-3 to R-4 per inch gives R-11.81 to R-15.75, or RSI 2.08 to 2.77 m²·K/W, the figure most metric codes and product sheets use.
Estimating heat loss through a wall
With the default wall, enter 200 ft² and a 40 °F temperature difference. Heat flow through the insulated cavity area is Q = A × ΔT ÷ R, about 526 to 663 Btu/h. In metric, 20 m² at a 20 °C difference works out to about 149 to 188 W.
Quick reference
R-value by thickness (h·ft²·°F/Btu, DOE R-per-inch ranges)
| Material | 1" | 2" | 3.5" | 5.5" | 6" | 10" | 12" |
|---|---|---|---|---|---|---|---|
| Fiberglass batt (standard density) | 2.9–3.8 | 5.8–7.6 | 10.2–13.3 | 16–20.9 | 17.4–22.8 | 29–38 | 34.8–45.6 |
| Fiberglass batt (high density) | 3.7–4.3 | 7.4–8.6 | 13–15 | 20.4–23.7 | 22.2–25.8 | 37–43 | 44.4–51.6 |
| Fiberglass, blown loose-fill | 2.2–2.7 | 4.4–5.4 | 7.7–9.5 | 12.1–14.9 | 13.2–16.2 | 22–27 | 26.4–32.4 |
| Fiberglass, blown dense-pack | 3.6–4.4 | 7.2–8.8 | 12.6–15.4 | 19.8–24.2 | 21.6–26.4 | 36–44 | 43.2–52.8 |
| Cellulose, blown loose-fill | 2.9–3.4 | 5.8–6.8 | 10.2–11.9 | 16–18.7 | 17.4–20.4 | 29–34 | 34.8–40.8 |
| Cellulose, dense-pack | 3–3.4 | 6–6.8 | 10.5–11.9 | 16.5–18.7 | 18–20.4 | 30–34 | 36–40.8 |
| Mineral wool (batt or loose-fill) | 3.7 | 7.4 | 13 | 20.4 | 22.2 | 37 | 44.4 |
| Cotton batt | 3.4 | 6.8 | 11.9 | 18.7 | 20.4 | 34 | 40.8 |
| Sheep's wool batt | 3.5 | 7 | 12.3 | 19.3 | 21 | 35 | 42 |
| Expanded polystyrene (EPS) board | 3–4 | 6–8 | 10.5–14 | 16.5–22 | 18–24 | 30–40 | 36–48 |
| Extruded polystyrene (XPS) board | 5 | 10 | 17.5 | 27.5 | 30 | 50 | 60 |
| Polyisocyanurate (polyiso) board | 5.6–8 | 11.2–16 | 19.6–28 | 30.8–44 | 33.6–48 | 56–80 | 67.2–96 |
| Open-cell spray foam | 3.5–3.8 | 7–7.6 | 12.3–13.3 | 19.3–20.9 | 21–22.8 | 35–38 | 42–45.6 |
R-value to RSI and U-factor conversion
| R (IP) | RSI (m²·K/W) | U (Btu/h·ft²·°F) | U (W/m²·K) |
|---|---|---|---|
| R-5 | 0.88 | 0.2 | 1.14 |
| R-8 | 1.41 | 0.125 | 0.71 |
| R-11 | 1.94 | 0.0909 | 0.516 |
| R-13 | 2.29 | 0.0769 | 0.437 |
| R-15 | 2.64 | 0.0667 | 0.379 |
| R-19 | 3.35 | 0.0526 | 0.299 |
| R-21 | 3.7 | 0.0476 | 0.27 |
| R-30 | 5.28 | 0.0333 | 0.189 |
| R-38 | 6.69 | 0.0263 | 0.149 |
| R-49 | 8.63 | 0.0204 | 0.116 |
| R-60 | 10.57 | 0.0167 | 0.0946 |
Fixed building layers and air films (ASHRAE design values)
| Material | R (IP) | RSI (m²·K/W) |
|---|---|---|
| Inside air film – wall | 0.68 | 0.12 |
| Inside air film – ceiling (heat flow up) | 0.61 | 0.11 |
| Outside air film (15 mph wind) | 0.17 | 0.03 |
| Gypsum board 1/2" | 0.45 | 0.08 |
| Gypsum board 5/8" | 0.56 | 0.1 |
| Plywood 1/2" | 0.62 | 0.11 |
| OSB 7/16" | 0.62 | 0.11 |
Frequently asked questions
How is the total R-value calculated?
For layers stacked one behind another, heat flows through each in series, so the total R-value is the sum of every layer's R-value, including the inside and outside air films. The U-factor is the reciprocal, U = 1 ÷ R total. For example, R-12.07 gives U = 1 ÷ 12.07 ≈ 0.083 Btu/h·ft²·°F.
Where do the material R-values come from?
Insulation R-per-inch values come from Table 3.2 of the US DOE Building America guide Energy Renovations—Insulation (PNNL, 2012). Air films, gypsum board, plywood, and OSB use design values from the ASHRAE Handbook—Fundamentals. In the US, the FTC's R-value Rule (16 CFR Part 460) requires home insulation products to disclose their R-value, so a product label or data sheet is the best source for a specific product.
Why is the result shown as a range?
The DOE table gives a range for several materials, for example R-2.9 to R-3.8 per inch for standard-density fiberglass batts, because R-value varies with density and product. Rather than invent a single midpoint, the calculator carries the low and high values through. Enter your product's labeled R-value as a custom layer to get one number.
Why is my wall's real R-value lower than this?
This is a series calculation through the insulated cavity. Wood or steel studs, plates, and headers conduct heat around the insulation, so the whole-wall value is lower; steel framing reduces it sharply. Compressed or poorly fitted batts and gaps also lose R-value. A whole-assembly value requires a parallel-path or other framing-aware method.
How do I convert R-value to RSI?
RSI (m²·K/W) = R (h·ft²·°F/Btu) × 0.1761, and R = RSI × 5.678. So R-19 is about RSI 3.35 and R-38 is about RSI 6.69. U-values convert the other way: W/m²·K = Btu/h·ft²·°F × 5.678.
How is heat flow calculated?
Steady-state conduction is Q = A × ΔT ÷ R. In imperial units, area in ft², temperature difference in °F, and R in h·ft²·°F/Btu give Btu/h; in metric, m², °C (or K), and RSI give watts. This ignores air leakage, solar gain, and thermal mass, so it is a conduction estimate, not a full heating load.
Why aren't closed-cell spray foam or air spaces in the list?
The DOE table we use lists closed-cell spray foam at R-7 to R-9 per inch, which is higher than figures commonly published elsewhere, so we left it out rather than present a doubtful number. The R-value of an enclosed air space depends on its width, orientation, heat-flow direction, and surface emissivity. For either, enter the manufacturer's labeled value or a value from the ASHRAE tables as a custom layer.