Hardness Conversion Calculator
Convert material hardness between Rockwell, Brinell, and Vickers scales.
Rockwell C (HRC)
45
Brinell (HB)
≈421
Vickers (HV)
≈446
Rockwell B (HRB)
N/A
Usage examples
Checking a heat-treated tool steel's spec sheet
Convert an HRC hardness value from a spec sheet to HB to compare it against a different material's datasheet.
Reading a Brinell value off a material test report (MTR)
Use a supplier's HB value to get a rough sense of the equivalent HRC hardness range.
Comparing a Vickers microhardness test result
Convert a small part's Vickers hardness reading to the more commonly quoted Rockwell C scale.
Frequently asked questions
How accurate are these conversions?
They're reference-grade approximations. The relationship between hardness scales isn't a clean mathematical formula — it comes from empirical correspondence tables derived from real testing, most authoritatively standardized for steel in references like ASTM E140. This tool interpolates between sampled points from that kind of widely-published reference table. For tolerance verification or certification, you need an actual physical hardness test on the relevant scale.
Can I use this for non-steel materials like aluminum or brass?
It's not recommended. These conversion tables are calibrated for steel. Other materials — aluminum, brass, plastics — have a different relationship between hardness and strength, so applying the same table to them can introduce significant error.
Why doesn't Brinell (HB) show a value above HRC 50?
A standard Brinell test (especially with a common carbide-ball indenter) becomes unreliable on very hard materials — the indenter itself can deform, and results lose accuracy — so in practice Brinell isn't used much above roughly HB 500 (≈HRC 50). Harder materials are typically measured with Rockwell C or Vickers instead. This tool won't show an HB estimate in a range it isn't reliable.
Why doesn't Rockwell B (HRB) convert directly to Rockwell C or Vickers?
Rockwell B is a separate scale used for comparatively soft materials — annealed mild steel, aluminum, brass. We couldn't find a reliably sourced table that bridges HRB directly to HRC/HV, so this tool only converts HRB to HB and doesn't chain it further. We'd rather narrow the scope than fabricate a bridge we're not confident in.
What happens if I enter a value outside the supported range?
The tool shows a clear out-of-range message instead of a number. We'd rather be upfront about not covering that range than invent a number from data we don't actually have.